Operational Qualification (Click to enlarge image) We have ten moulding machines in our workshop to perform the Operational Qualification. However, our new Customer Service Centre features a number of validation cells that allow you to install your machine at our premises and perform the OQ on site.

Based on the First Off Inspection Report (FOIR), which is generated by us, our customer or a metrology lab, we optimize the steel dimensions in the mould. We verify the effect of these corrections with an additional verification run. After updating the FOIR, the mould is ready for shipment and to complete the validation with the Performance Qualification (PQ) at your facility.

We always invite our clients to attend the First Out Of Tool (FOT), the OQ or the verification run, so it can simultaneously function as the official Factory Acceptance Test (FAT) to release the mould for delivery.